Capture emissions at the source
Identify the emission points, operating schedule, airflow, temperature and pollutant characteristics. A collector cannot compensate for an ineffective capture hood or an unsuitable duct network.
Match the collector to the duty
Cyclones use centrifugal separation and are often considered for coarser particles. Bag filters capture particles on a filtration medium. Wet scrubbers contact gas with liquid and must be selected for the target pollutant and chemistry. Assess dust moisture, stickiness, corrosion and maintenance requirements.
Check the complete system
Review pressure loss, fan selection, cleaning arrangements and collected-waste handling. Scrubber blowdown may need treatment. Establish inspection and monitoring requirements for the actual site.